MMC Test Cord
Built for High-Density Testing, Validation, and Large-Capacity Fiber Deployments
Low insertion loss and high return loss
AR coating, supporting multiple plugs more than 500 times
MMC Test Cord
Products Description
The MMC connector features high density, low insertion loss connectivity by combining a reduced size, MT-style ferrule (TMT) with a novel very small form factor (VSFF) connector. MMC Test cord, as the highest grade, is used for testing, validation, and deployment support in high-density fiber environments.
MMC test cord has low insertion loss <0.2dB, 100% IEC End-Face Inspected, and every connector assembly is inspected to IEC 61300-3-35, with end-face geometry controlled to IEC 61755-3-31 for consistent optical performance and deployment reliability. It will satisfy the velification and acceptance across multiple data center application spaces, including structured cabling, high fiber count data center interconnects, transceivers and on-board optics.

Key features
--Higher port density, more efficient for new-gen solution
--AR coating endface ensures durable use for harsh and frequent application
--Optional MMC12, MMC16, MMC24 (Male & Female)
--100% IEC End-Face Inspected with report
Product Specifications
| Fiber type | Corning / YOFC, OS2 9/125nm |
| Working wavelength (nm) | 1310nm 1550nm |
| Cable outside diameter (mm) | 2.5mm |
| Fiber counts | 12 / 16 / 24 |
| Minimum cable bend diameter | 20D / 10D |
| MMC connector IL (dB) | ≤0.20dB |
| MMC connector RL (dB) | ≥60dB |
| Polarity | Ribbonflip / Ribbon straight |
| Tensile strength (short-term) | 100N |
| Tensile strength(long-term) | 30N |
| Plug times | ≥ 500 |
| End-face polishing | AR coating |
| Operating temperature (℃) | -20 to 70℃ |
| Storage temperature (℃) | -40 to 85℃ |
Application Scenarios
• High-Density testing and validation
• Ultra-low loss connections in data center
• CPO (Co-packaged optics) assemblies production line
FAQ
Q: What is the expected loss rate for MMC Test cord?
A: MMC test cord insertion-loss performance of less than 0.20 dB, return-loss performance of no less than -60 dB.
Q: In what fiber counts are MMC test cord available?
A: MMC test cord offers MMC12, MMC 16, MMC24 TMT ferrule options.
Q: What are the advantages of MMC connectors over standard MPO/MTP connectors?
A: MMC connectors use a VSFF design to maximize the port density, enabling up to three times the cabling port density when compared with MPO/MTP connectors. This enables higher bandwidth per rack unit for multiple applications, including structured cabling, hyperscale data center connectivity, transceivers and onboard optics.