AR SN-MT Test Cable
Built for High-Density Testing, Validation, and Large-Capacity Fiber Deployments
Low insertion loss and high return loss
AR coating, supporting multiple plugs more than 500 times
AR SN-MT Test Cable
Products Description
SN-MT connector is a Very Small Form Factor (VSFF) designed to handle the growing density and bandwidth requirements of modern data centers. SENKO's SN and SN-MT connectors are engineered to support the seamless evolution from traditional duplex applications to advanced 8-lane octal designs. It allows 2.7x increase density compared to MTP/MPO-16 connectors.
AR SN-MT test cable is an upgrade version, with its ferrule AR coated. It helps to increase the plug/unplug durability, which is very crucial for applicaitons like testing, network acceptance and maintenance.

(image from Senko, contact to delete if any infringement)
Key features
--Higher port density, more efficient for CPO ecology deployment
--AR coating endface ensures multiple plug&unplug scenarios
--100% IEC End-Face Inspected with report
Product Specifications
| Connector type | SENKO SN-MT |
| Working wavelength (nm) | 1310nm 1550nm |
| Cable outside diameter (mm) | 2.5mm |
| Fiber counts | 8 / 16 |
| Connector IL (dB) | ≤0.35dB |
| Connector RL (dB) | ≥60dB |
| Plug times | ≥ 500 |
| End-face polishing | AR coating |
| Operating temperature (℃) | -20 to 70℃ |
| Storage temperature (℃) | -40 to 85℃ |
Application Scenarios
• High-Density testing and validation
• Ultra-low loss connections in harsh enviroment
• CPO (Co-packaged optics) assemblies production line
FAQ
Q: What is the specificaiton of SN-MT density?
A: SN-MT has the same external dimensions as the SN connector, its density is approximately 2.7 times that of MPO-16F A single QSFP-DD or OSFP optical module can accommodate 4 SN-MTs
Q: Is SN-MT compatible with MMC?
A: SN-MT and MMC are incompatible, as they are independent connector standards dominated by different manufacturers (US CONCEC, SENKO)with different physical interfaces and plug structures, cannot be directly plugged in or mixed
Q: What are the use scenarios of SN-MT test cable?
A: SN-MT test cable is mainly used in the production, deployment, and daily maintenance of SN-MT high-density fiber optic connectors to detect whether the insertion loss, return loss, and polarity of these connectors meet the standards.